Send inquiry
Radiant Floor Heating Cable of UL approved E481865
Senphus products underfloor single conductor and twin conductor underfloor heating cable mainly.
The Senphus Radiant Heating Cables are the professional underfloor heating solution for screed projects with all you need in one box. For larger areas, simply buy two or more kits.
The Radiant Heating Cable do not have to be installed by an electrician. They can be installed by anyone who follows the installation instructions carefully. However, a suitably qualified electrician must check the installation, connect up to the mains supply and issue the appropriate documentation.
The Radiant Heating Cable is installed into a 50-75mm sand and cement screed.
Senphus also offers a lifetime on all its products.
Insulation:
Current Building Regulations stipulate requirements for floor insulation but you can never provide too much insulation! Running costs of the heating system are determined by the room or dwelling's heat loss so any expenditure on insulation will be repaid many times over. We recommend that you regard Building Regulation requirements as the 'bare minimum' and install additional insulation. We supply Senphus Insulation Boards and Senphus Insulated Tile Backer Boards available in sheet form with a K value (thermal conductivity) of 0.029W/m°K.
Thermostat:
The kit includes our advanced Senphus R8600 16A fully programmable thermostat. It boasts some of the following features:
Factory Pre-Set Date & Time
Factory Pre-Set program
Clock automatically adjusts for BST
ON ~ OFF switch
Battery Back-up of Date & Time
EPROM Back-up for program.
Child-lock/Pin-lock Features
+Many other features
Electrical Requirements:
The heating elements are simple to install by following the comprehensive installation instructions.
The final electrical connections should be made by a qualified electrician in accordance with the current regulations.
All installations require a 30mA RCD (residual current device) for safe operation.
Thermostats are now permitted to be installed in a bathroom outside of Zone 2 under 17th Edition rules. Refer to section 701-753 of BS 7671:2008 for further details.
Let's introduce the underfloor heating cable as follows:
Senphus radiant heating cable of 15w/m
Senphus radiant heating cable of 20w/m
We are specilized in all kinds of radiant floor heating cable with the competitive price.
Senphus radiant heating cables are very thin and short lead time.
Senphus products underfloor single conductor and twin conductor underfloor heating cable mainly.
The Senphus Radiant Heating Cables are the professional underfloor heating solution for screed projects with all you need in one box. For larger areas, simply buy two or more kits.
The Radiant Heating Cable do not have to be installed by an electrician. They can be installed by anyone who follows the installation instructions carefully. However, a suitably qualified electrician must check the installation, connect up to the mains supply and issue the appropriate documentation.
The Radiant Heating Cable is installed into a 50-75mm sand and cement screed.
Senphus also offers a lifetime on all its products.
Insulation:
Current Building Regulations stipulate requirements for floor insulation but you can never provide too much insulation! Running costs of the heating system are determined by the room or dwelling's heat loss so any expenditure on insulation will be repaid many times over. We recommend that you regard Building Regulation requirements as the 'bare minimum' and install additional insulation. We supply Senphus Insulation Boards and Senphus Insulated Tile Backer Boards available in sheet form with a K value (thermal conductivity) of 0.029W/m°K.
Thermostat:
The kit includes our advanced Senphus R8600 16A fully programmable thermostat. It boasts some of the following features:
Factory Pre-Set Date & Time
Factory Pre-Set program
Clock automatically adjusts for BST
ON ~ OFF switch
Battery Back-up of Date & Time
EPROM Back-up for program.
Child-lock/Pin-lock Features
+Many other features
Electrical Requirements:
The heating elements are simple to install by following the comprehensive installation instructions.
The final electrical connections should be made by a qualified electrician in accordance with the current regulations.
All installations require a 30mA RCD (residual current device) for safe operation.
Thermostats are now permitted to be installed in a bathroom outside of Zone 2 under 17th Edition rules. Refer to section 701-753 of BS 7671:2008 for further details.
Let's introduce the underfloor heating cable as follows:
Senphus radiant heating cable of 15w/m
Voltage | Size | Power/W | Ohm | Length(m) | w/m |
230 | SHDN-15-10M(P) | 150 | 352.67 | 10 | 15 |
230 | SHDN-15-15M(P) | 225 | 235.11 | 15 | 15 |
230 | SHDN-15-25M(P) | 375 | 141.07 | 25 | 15 |
230 | SHDN-15-30M(P) | 450 | 117.56 | 30 | 15 |
230 | SHDN-15-35M(P) | 525 | 100.76 | 35 | 15 |
230 | SHDN-15-42.5M(P) | 637.5 | 82.98 | 42.5 | 15 |
230 | SHDN-15-60M(P) | 900 | 58.78 | 60 | 15 |
230 | SHDN-15-80M(P) | 1200 | 44.08 | 80 | 15 |
230 | SHDN-15-90M(P) | 1350 | 39.19 | 90 | 15 |
230 | SHDN-15-100M(P) | 1500 | 35.27 | 100 | 15 |
230 | SHDN-15-120M(P) | 1800 | 29.39 | 120 | 15 |
230 | SHDN-15-140M(P) | 2100 | 25.19 | 140 | 15 |
230 | SHDN-15-160M(P) | 2400 | 22.04 | 160 | 15 |
SHDN-20W/M(A) | ||||||
Voltage | Size | Power/W | Voltage | Resistance @20oC+10/-5% |
Length(m) | The power line length |
230V | SHDN-20-15M(A) | 300 | 230 | 176.33 | 15 | 3C 0.5mm2 L=2M black |
230V | SHDN-20-25M(A) | 500 | 230 | 105.80 | 25 | 3C 0.5mm2 L=2M black |
230V | SHDN-20-30M(A) | 600 | 230 | 88.17 | 30 | 3C 0.5mm2 L=2M black |
230V | SHDN-20-35M(A) | 700 | 230 | 75.57 | 35 | 3C 0.75mm2 L=2M black |
230V | SHDN-20-42.5M(A) | 850 | 230 | 62.24 | 42.5 | 3C 0.75mm2 L=2M black |
230V | SHDN-20-60M(A) | 1200 | 230 | 44.08 | 60 | 3C 0.75mm2 L=2M black |
230V | SHDN-20-80M(A) | 1600 | 230 | 33.06 | 80 | 3C 1.0mm2 L=2M black |
230V | SHDN-20-90M(A) | 1800 | 230 | 29.39 | 90 | 3C 1.0mm2 L=2M black |
230V | SHDN-20-100M(A) | 2000 | 230 | 26.45 | 100 | 3C 1.0mm2 L=2M black |
230V | SHDN-20-120M(A) | 2400 | 230 | 22.04 | 120 | 3C 1.5mm2 L=2M black |
230V | SHDN-20-140M(A) | 2800 | 230 | 18.89 | 140 | 3C 1.5mm2 L=2M black |
230V | SHDN-20-160M(A) | 3200 | 230 | 16.53 | 160 | 3C 1.5mm2 L=2M black |
We are specilized in all kinds of radiant floor heating cable with the competitive price.
Senphus radiant heating cables are very thin and short lead time.