10000-class clean area standard
according to the number of dust particles and to define the number of microorganisms
1.The maximum number of dust particles (per cubic meter) to allow:
Large or equal to the number of particles of 0.5 microns can not be more than 350,000,
Greater or equal to the number of particles 5 microns not more than 2000;
2.The maximum allowable number of microorganisms:
Planktonic bacteria not more than 100 per cubic meter:,
Settlement of bacteria not more than 3 per dish.
USA Federal Standard 209E(1992 Year)
Clean standard Particle size(um)
  0.1 0.2 0.3 0.5 5
10000 NA NA NA 10000 70.3
 Units: quntity of dust/ft3 
 China pharmaceutical manufacturing clean room (area) of air cleanliness standard
Clean standard quntity of dust/M3  Maximum allowable quantity of microorganisms
  ≥0.5um ≥5um Float bacteria PS/M3 Subsidence bacteria PS/30min
10000 350,000 2,000 100 3  
China Drug Administration of August 1, 1999 issued and implemented