Digital Meter, Hz Meter, Single Phase (DP3)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-01 23:05

  • Browse the number:

    168

Send an inquiries

Company Profile

Yueqing JYins Electric Technology Co., Ltd.

By certification [File Integrity]

Contact:Mr. Hoffer(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website: http://jyinschina.artstx.com/

Product details
Clear display, stable and reliable, it has kinds of models to be chosen, special model is custom made with users'requirement.

Technical index
Max display: ± 1999;
Input way: Single input;
Sotore temperature: 0~40º C
Accuracy: ± 0.5%range± 1;
Measure speed: 2.5times/s;
Power: AC 100V 220V-DC 5V 12V 24V;

Product overview:
JYX-DP3(SXDP3) (PZ1006-3) single-phase digital meter adopts alternating current sampling techniques, which enables it to measure the power in ammeter, voltmeter, frequency meter in the power grid, with its high accuracy, good stability, good resistance to vibration, and intuitive display. It is convenient to install, easy to wire, and simple to maintain, and it's an upgraded product of various types of the pointer headers.


Product parameters:
1&period; Power Supply&colon; AC&sol;DC&colon; 80V-270V 2&period; Accuracy&colon; ≤ 0&period;5&percnt; of the full input scale ± 2 characters&period; 3&period; Sampling rate&colon; About 2&period;5 times&sol;second&period; 4&period; Temperature&colon; 0 ~ 40&period;5&period; Frequency Response&colon; 50 ~ 60&period;6&period; Power consumption&colon; <3&period;2VA 7&period; Maximum signal loss&colon; <0&period;5VA&period;
Product functions&colon;
Measurement&colon; Ammeter&comma; voltmeter&comma; frequency meter&period; Display&colon; Three and a half digital LED display &lpar;red&rpar;&period; Maximum input&colon; Voltmeter&colon; 600V&comma; voltage transformer is required when the AC voltage is over 600V&semi; Ammeter&colon; 5A&comma; current transformers is required when the AC current is over 5A&period; DC ammeter&colon; 5A&comma; shunts of 75mv&comma; 60mv and 50mv are required when the DC current is over 5A&period; Uses&colon; Suitable for measuring the parameters in ammeter&comma; voltmeter&comma; and frequency meter in the industries of electric power grids&comma; automation&comma; substation automation&comma; power distribution automation&comma; intelligent building&comma; and the enterprise's internal system&period; Time aging&colon; All the products have been time-aged&comma; so that it can stably work in a long-term to reduce the impact of external environment on the meter&comma; offering users a satisfactory product&period;
model
 
range
 
distinguish
 
Input resistance
 
Transformer various
 
Accuracy
 
Max input
 
AC& DC Voltage
 
199&period;9mV
 
100 μ V
 
5M &ohm;
 
Direct input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
5V
 
1&period;999V
 
1mV
 
5M &ohm;
 
Direct input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
10V
 
19&period;99V
 
10 mV
 
5M &ohm;
 
Direct input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
50V
 
199&period;9V
 
100 mV
 
5M &ohm;
 
Direct input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
500V
 
600V
 
1V
 
5M &ohm;
 
Direct input
 
± 1&percnt;F&period; S ± 2Digit
 
1000V
 
AC& DC Current
 
19&period;99mV
 
10 Μ v
 
10 &ohm;
 
Direct input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
500mA
 
199&period;9mV
 
100 μ V
 
1 &ohm;
 
Direct input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
1A
 
1&period;99V
 
1mV
 
0&period;1 &ohm;
 
Direct inputor CT input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
5A
 
5A
 
10 mV
 
0&period;1 &ohm;
 
Direct inputor CT input
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
10A
 
> 19&period;99V
 
100 mV
 
0&period;01 &ohm;
 
5A or 75mV
 
± 0&period;5&percnt;F&period; S ± 2Digit
 
25A