Gauge Pressure Transmitter with Remote Diaphragm Seal for Liquids, Gas (ATEX Approved)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shaanxi

  • Validity to:

    Long-term effective

  • Last update:

    2017-09-28 15:25

  • Browse the number:

    126

Send an inquiries

Company Profile

Xi'an Tosilon Automation Co., Ltd.

By certification [File Integrity]

Contact:Mr. Mason. Ding(Mr.)  

Email:

Telephone:

Phone:

Area:Shaanxi

Address:Shaanxi

Website: http://tosilon.artstx.com/

Product details
Tosilon Gauge Pressure Transmitter with Remote Diaphragm Seal for Liquids, Gas (ATEX Approved)
Design and Manufacturing according to ATEX Standard

General Description
The high performance pressure transmitter RP1002/3-A is suitable to measure liquid, gas, or
steam flow as well as liquid level, density and pressure. RP1002/3-A outputs a 4-20mA DC signal
corresponding to the measured pressure. The key feature include quick response, remote set-up
using communications, self-diagnostics and optional status output for pressure high/low alarm.m.

Span & Range Limits
Span/
Range Limits
kPa psi bar Kgf/cm2
C/S Span 2~40 0.29~5.8 0.02~0.4 0.02~0.4
Range
Limits
-40~40 -5.8~5.8 -0.4~0.4 -0.4~0.4
D Span 2.5~250 0.3625~36.25 0.025~2.5 0.025~2.5
Range
Limits
-100~250 -14.5~36.25 -1~2.5 -1~2.5
F Span 30~3000 4.35~435 0.3~30 0.3~30
Range
Limits
-100~3000 -14.5~435 -1~30 -1~30
G Span 0.1~10MPa 14.5~1450 1~100 1~100
Range
Limits
-0.1~10MPa -14.5~1450 -1~100 -1~100
H Span 0.21~21Mpa 30.45~3045 2.1~210 2.1~210
Range
Limits
-0.1~21MPa -14.5~8000 -1~210 -1~210
I Span 0.4~40MPa 58~5800 4~400 4~400
Range
Limits
-0.1~40MPa -14.5~5800 -1~400 -1~400
 
Span/
Range Limits
kPa psi bar Kgf/cm2
M Span 2.5~250 2.5~250 0.025~2.5 0.025~2.5
Range
Limits
0~250 0~250 0~2.5 0~2.5
O Span 30~3000 30~3000 0.3~30 0.3~30
Range
Limits
0~3000 0~3000 0~30 0~30

EMC Performance Table
Items Test Items Basic Standard Test Condition Performance Level
1 Radiated Interference (Housing) GB/T 9254-2008 30 MHz~1000 MHz OK
2 Conducted Interference
(DC Power Port)
GB/T 9254-2008 0.15 MHz~30 MHz OK
3 Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006 4kV (Line)
8kV (Air)
B
4 RF Electromagnetic Field
Immunity
GB/T 17626.3-2006 10V/m (80 MHz~1 GHz) A
5 Frequency Magnetic Field
Immunity
GB/T 17626.8-2006 30A/m A
6 Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV/(5/50ns, 5kHz) B
7 Surge Immunity GB/T 17626.5-2008 1kV (Line to Line)
2kV (Line to Ground)
(1.2us/50us)
B
8 Conducted Interference
Immunity induced by RF Field
GB/T 17626.6-2008 3V (150 KHz ~ 80 MHz) A

Dimensions



 
For more information, please contact Tosilon
Your Global Partner for Automation