High Temperature Differential Pressure Transmitter for Gas, Steam (ATEX Approved)

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shaanxi

  • Validity to:

    Long-term effective

  • Last update:

    2017-07-14 20:43

  • Browse the number:

    223

Send an inquiries

Company Profile

Xi'an Tosilon Automation Co., Ltd.

By certification [File Integrity]

Contact:Mr. Mason. Ding(Mr.)  

Email:

Telephone:

Phone:

Area:Shaanxi

Address:Shaanxi

Website: http://tosilon.artstx.com/

Product details
Tosilon High Temperature Differential Pressure Transmitter for Gas, Steam (ATEX Approved)
Design and Manufacturing according to ATEX Standard

General Description
The high performance differential pressure transmitter RP1001-A is suitable to measure liquid, gas, or steam flow as well as liquid level, density and pressure.

RP1001-A outputs a 4-20mA DC signal corresponding to the measured differential pressure. Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via HART communications.

Other key features include quick response, remote set-up using communications, self-diagnostics and optional status output for pressure high/low alarm.

Span & Range Limits
Span/
Range
Limits
kPa inH20 mbar mmH20
C Span 0.4~40 1.6~160 4~400 40~4000
Range
Limits
-40~40 -160~160 -400~400 -4000~4000
D Span 2.5~250 10~1000 25~2500 0.25~25mH2O
Range
Limits
-250~250 -1000~1000 -2500~2500 -25~25mH2O
E Span 20~2000 80~8000 0.2~20 bar 2~200mH2O
Range
Limits
-500~2000 -2000~8000 -5~20 bar -5~200mH2O

EMC Performance Table
Items Test Items Basic Standard Test Condition Performance Level
1 Radiated Interference (Housing) GB/T 9254-2008 30 MHz~1000 MHz OK
2 Conducted Interference
(DC Power Port)
GB/T 9254-2008 0.15 MHz~30 MHz OK
3 Electrostatic Discharge (ESD)
Immunity
GB/T 17626.2-2006 4kV (Line)
8kV (Air)
B
4 RF Electromagnetic Field
Immunity
GB/T 17626.3-2006 10V/m (80 MHz~1 GHz) A
5 Frequency Magnetic Field
Immunity
GB/T 17626.8-2006 30A/m A
6 Electrical Fast Transient Burst
Immunity
GB/T 17626.4-2008 2kV/(5/50ns, 5kHz) B
7 Surge Immunity GB/T 17626.5-2008 1kV (Line to Line)
2kV (Line to Ground)
(1.2us/50us)
B
8 Conducted Interference
Immunity induced by RF Field
GB/T 17626.6-2008 3V (150 KHz ~ 80 MHz) A

Dimensions




 
For more information, please contact Tosilon
Your Global Partner for Automation
www.tosilon.com