Model specification |
HF-2 | HF-5 | HF-10 | HF-20 | HF-50 | HF-100 | HF-200 | HF-500 | HF-1000 | |
Peak load value |
N | 2 | 5 | 10 | 20 | 50 | 100 | 200 | 500 | 1000 |
kg | 2 | 0.5 | 1 | 2 | 5 | 10 | 20 | 50 | 100 | |
lbs | 0.44 | 1.1 | 2.2 | 4.4 | 11 | 22 | 44 | 110 | 220 | |
load division value |
N | 0.001 | 0.001 | 0.01 | 0.01 | 0.01 | 0.1 | 0.1 | 0.1 | 1 |
kg | 0.0001 | 0.0001 | 0.001 | 0.001 | 0.001 | 0.01 | 0.01 | 0.01 | 0.1 | |
lbs | 0.0001 | 0.0001 | 0.001 | 0.001 | 0.001 | 0.01 | 0.01 | 0.01 | 0.1 | |
Indication error |
0.50% | |||||||||
Unit | N / kg / lb | |||||||||
Data interface |
Rs232 nine-hole socket | |||||||||
Power | rechargeable batteries, charger(charging voltage 100V-240V) | |||||||||
Sensor structure |
S-tye sensor with high precision (inner sensor) | |||||||||
Ambient temp. |
5° C~35° C | |||||||||
Transport temp. |
-10 C~60° C | |||||||||
Relative humidity | 15%~80%RH | |||||||||
Working conditions | No hypocenter and corrosive medium | |||||||||
Gross weight | ~2000g | |||||||||
Size | 273 x 182 x70 mm |
Model | HF-2000 | HF-5000 | HF-10K | HF-20K | HF-50K | HF-100K | HF-200K | HF-500K | HF-1000K | |||
Peak load value |
2000N | 5000N | 10KN | 20KN | 50KN | 100KN | 200KN | 500KN | 1000KN | |||
load division value |
1N | 1N | 0.01KN | 0.01KN | 0.01KN | 0.1KN | 0.1KN | 0.1KN | 1KN | |||
0.1kg | 0.1kg | 0.001kg | 0.001kg | 0.001kg | 0.01kg | 0.01kg | 0.01kg | 0.1kg | ||||
0.1lbs | 0.1lbs | 0.001Klbs | 0.001Klbs | 0.001Klbs | 0.01Klbs | 0.01Klbs | 0.01Klbs | 0.1Klbs | ||||
Indication error |
±1% | ±1% | ||||||||||
Unit | N / (KN), kg / (Mg or t), lb (KIb) | |||||||||||
Data interface |
Rs232 nine-hole socket | |||||||||||
Power | rechargeable batteries, charger(charging voltage 100V-240V) | |||||||||||
Sensor structure |
S-tye or column sensor with high precision (external sensor) | |||||||||||
Ambient temp. |
5° C~35° C | |||||||||||
Transport temp. |
-10° C~60° C | |||||||||||
Relative humidity |
15%~80%RH | |||||||||||
Working conditions |
No hypocenter and corrosive medium | |||||||||||
Gross weight |
6 kg | 9 kg | 24 kg | 36 kg | ||||||||
Size | 280 x 200 x 170 mm | 310 x 260 x 190 mm |
Model | HF-2000K | HF-3000K |
Peak load value | 2000KN | 3000KN |
load division value |
1KN | |
0.1Mg | ||
0.1Klb | ||
Indication error | ±1% | |
Unit | N / (KN), kg / (Mg or t), lb (Klb) | |
Data interface | Rs232 nine-hole socket | |
Power | rechargeable batteries, charger(charging voltage 100V-240V) | |
Sensor structure |
S-type or column sensor with high precision (external sensor) |
|
Ambient temperature |
5° C~35° C | |
Transport temperature |
-10° C~60° C | |
Relative humidity |
15%~80%RH | |
Working conditions |
No hypocenter and corrosive medium | |
Gross weight |
36 kg | |
Size | 310 x 260 x 190 mm |
Model | NK-20 | NK-30 | NK-50 | NK-100 | NK-200 | NK-300 | NK-500 |
Max load | 20N 2kg |
30N 3kg |
50N 5kg |
100N 10kg |
200N 20kg |
300N 30kg |
500N 50kg |
Min load | 2N 0.2kg |
3N 0.3kg |
5N 0.5kg |
10N 1kg |
20N 2kg |
30N 3kg |
50N 5kg |
Load graduation value | 0.1N 20g |
0.2N 20g |
0.25N 50g |
0.5N 100g |
1.0N 200g |
2.0N 200g |
2.5N 500g |
Rod journey | 10mm | ||||||
Work temperature | 20°+-10ºC | ||||||
Carry temperature | -27ºC~+70ºC | ||||||
Relative humidity | 15%~80%RH | ||||||
Work environment | No vibrancy and no cautery |
Model | ALB-4 | ALB-10 | ALB-20 | ALB-40 | ALB-100 |
Max load | 4.5Ib 2kg |
11Ib 5kg |
22Ib 10kg |
45Ib 20kg |
110Ib 50kg |
Min load | 0.45Ib 0.2kg |
1Ib 0.5kg |
2.2Ib 1.1kg |
4.5Ib 2.2kg |
11Ib 5.5kg |
Load graduation value | 0.02Ib 0.02kg |
0.05Ib 0.05kg |
0.1Ib 0.1kg |
0.2Ib 0.2kg |
0.5Ib 0.5kg |
Rod journey | 10mm | ||||
Work temperature | 20°+-10ºC | ||||
Carry temperature | -27ºC~+70ºC | ||||
Relative humidity | 15%~80%RH | ||||
Work environment | No vibrancy and no cautery |
Model | NLB-20 | NLB-30 | NLB-50 | NLB-100 | NLB-200 | NLB-300 | NLB-500 |
Max load | 20N 4.4Ib |
30N 6.6Ib |
50N 11Ib |
100N 22Ib |
200N 44Ib |
300N 66Ib |
500N 110Ib |
Min load | 2N 0.4Ib |
3N 0.6Ib |
5N 1Ib |
10N 2Ib |
20N 4Ib |
30N 6Ib |
50N 10Ib |
Load graduation value | 0.1N 0.04Ib |
0.2N 0.04Ib |
0.25N 0.1Ib |
0.5N 0.2Ib |
1.0N 0.4Ib |
2.0N 0.4Ib |
2.5N 1.0Ib |
Rod journey | 10mm | ||||||
Work temperature | 20°+-10ºC | ||||||
Carry temperature | -27ºC~+70ºC | ||||||
Relative humidity | 15%~80%RH | ||||||
Work environment | No vibrancy and no cautery |