Medical and Lab Semi-Auto Urine Chemistry Analyzer Test Equipment with Free Strips

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Jiangsu

  • Validity to:

    Long-term effective

  • Last update:

    2017-10-13 09:10

  • Browse the number:

    88

Send an inquiries

Company Profile

Nanjing Mineddy Medical Equipment Co., Ltd.

By certification [File Integrity]

Contact:Mr. Roadrick(Mr.)  

Email:

Telephone:

Phone:

Area:Jiangsu

Address:Jiangsu

Website: http://mineddy.artstx.com/

Product details
Product Description

Product Parameter
 

Light Source: 6V 10W, halogen lamp of more than 2000 hours' life time 

Spectrometer: interference filter. 

Wavelength: 340nm,380nm,405nm,505nm,546nm,578nm,620nm, and one wavelength free. 

CML precision: ±2nm 

FWHM: ≤10nm 

Stray light:≤0.5%(absorbance≥2.5) 

Absorbance range: -0.214~3.000 

Absorbance linearity: ±1% 

Absorbance repeatability: ±0.001 

Absorbance resolution: 0.0001 

Precision: ≤1.0% 

Carry over: ≤1% 

Temperature: 25°C,30°C,37°C,±0.3°C 

Flow cell:permanent quartz flow cell, minimal volume is 32μL, and disposable flow cell is selectable 

Sampling system: pressure auto releasing pumps ensure the accuracy of suction volume 

Operational system: VISTA,Windows XP,Windows2000 

Test Method: End point,Fixed time,Kinetic,Factor,Muli-standards,Bichromatic,Dual wavelengths 

Parameter Setting: Patients' profile and calculated item can be set easily 

Absoption volume: 200μL~3000μL 

Sample volume: 10μL~50μL 

Reaction curve: real time display the reaction curve 

Memory: Able to store more than 200 parameters while 55 parameters of them are stablized ; 

Able to save more than 15000 test results and auto save the results if the power is off during working 

QC: auto draw the QC figure 

Reagent: Open reagent 

Display: LCD with high brightness 

Input: key button and touch screen 

Printer: Inner thermal printer,able to be connected to external printer

Report content: absorbance,concentration,activity, detailed patient information and abnormal results marking 

Interface: RS-232 serial port, able to be connected to computer 

Working Condition: Temperature:10°C~30°C;Relative Humidity:20%~80% 

Voltage: AC 85-264V,auto adapt according to the input voltage 

Power : ≤100W 

Quality System: Recognized by TUV and CMD 

Test item

Liver

ALT,ALP,GGT,TP,Alb,TBIL,DBIL

Heart

LDH,CK,CK-MB,AST, a-HBDH

Lipids

CHO,TG,HDL_C,LDL_C

Lipoprotein

Apo A1,Apo B,Lp(a)

kidney

BUN,CRE,UA

Ion

Na,Mg,Ca,K,P,Cl

Other

CO2-CP,AMS,LIP,GLU,IgA,IgG,IgM,C3,C4,CRP