Direct Fired Absorption Chiller

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shandong

  • Validity to:

    Long-term effective

  • Last update:

    2017-12-24 08:35

  • Browse the number:

    112

Send an inquiries

Company Profile

Dongguan Orste Machinery Equipment Co., Ltd.

By certification [File Integrity]

Contact:Ms. Meng(Mr.)  

Email:

Telephone:

Phone:

Area:Shandong

Address:Shandong

Website: http://lucysolar.artstx.com/

Product details


Specifications

Fuel-fired absorption chiller, double effect, the smallest is 58Kw, gas/oil/bio fired, and etc


Fuel -fired absorption chiller(Double effect)
1). Cooling capacity: 58Kw and above
2). Fuel: Natural gas or diesel oil or bio and etc
3). Refrigerator: Water
4). Absorber: Lithium bromide solution
5). Inhibitor: Lithium chromate or Lithium molybdate

NOTE:
1. Rated heating W. Inlet/outlet temp: 55-60° C.
2. Rated hot living W. Inlet/outlet temp: 40-60° C.
3. Fouling factor for chilled W., hot W., cooling W.: 0.086m2k/kw(0.0001m2h° C/Kcal).
4. Pressure limit for chilled W., cooling W.: 0.8MPa.
5. Oil consumption is calculated by low heating value: 10300Kcal/Kg
Coal gas is calculated by high heating value: 3560Kcal/Nm3
Natural gas is calculated by high heating value: 8650Kcal/Nm3
Model ZX-1 7 5D ZX- 200 D ZX-2 3 0D ZX-2 9 0D ZX- 350 D ZX-4 10 D ZX- 465 D ZX- 520 D
Cooling capacity KW 1745 2035 2326 2908 3489 4071 4652 5234
10 4 kcal/h 150 175 200 250 300 350 400 450
US BT 500 583 667 833 1000 1167 1333 1500
H eating capacity 10 4 kcal/h 126 147 168 210 252 294 336 3 78
US BT 420 490 560 700 840 980 1120 1260
C hilled water or heating water Flow rate m3/h 300 350 400 500 600 700 800 900
Pressure loss MPa 0.1 0.1 0.04 0.04 0.06 0.08 0.1 0.1
Connection diameter mm 200 250 250 250 300 300 350 350
Cooling water Flow rate m3/h 430 500 571 715 856 1000 1145 1288
Pressure loss MPa 0.08 0.08 0.09 0.09 0.1 0.09 0.1 0.11
Connection diameter mm 250 300 300 300 350 350 400 400
H ot water Flow rate m3/h 75 87 100 125 150 175 200 225
Pressure loss MPa 0.05 0.05 0.05 0.05 0.05 0.05 0.05 0.05
Connection diameter mm 125 125 125 150 150 150 200 200
Gas oil C onsumption C ooling kg/h 108 126.5 144 180 216 252 287.5 323.5
H eating kg/h 125.7 146.7 167.6 209.5 251.4 293.3 335.2 377.1
C onnection Dia. IN 1/2 1/2 1/2 1/2 1/2 1 1 1
Coal Gas Consumption C ooling Nm3/h 312 364 416.5 520 624 728 831.5 935.5
H eating Nm3/h 362.9 423.4 483.8 604.8 725.7 846.7 967.6 1088.6
C onnection Dia.  mm 80 100 100 100 125 125 125 125
Natural gas Consumption C ooling Nm3/h 128.5 150 171 213.5 256 299 341.5 384
H eating Nm3/h 149.3 174.2 199.1 248.9 298.7 348.4 398.2 478
C onnection Dia.  mm 80 80 80 100 100 100 100 100
Dimension Length mm 5670 6200 6880 6880 7400 7400 8300 8300
Weight  mm 3128 3000 3533 3533 3780 3780 3930 3930
Height mm 2919 3170 3210 3210 3590 3590 3850 3850
Shipping weigh t T 18.5 22 26 30 34 41 48 55